134 results for 'sampling sampling sampling sampling sampling sampling sampling sampling'
Search: 'sampling sampling sampling sampling sampling sampling sampling sampling'
134 Search:
Okt 1, 1996 ... Source Test Procedure ST-23 WATER VAPOR (Adopted January 20, 1982) 1. APPLICABILITY 1.1 This method is used to quantify the water vapor content of stack gases. It is applicable in all cases in which ...
Read MoreOkt 1, 1996 ... Source Test Procedure ST-23 WATER VAPOR (Adopted January 20, 1982) 1. APPLICABILITY 1.1 This method is used to quantify the water vapor content of stack gases. It is applicable in all cases in which ...
Okt 1, 1996 ... Source Test Procedure ST-22 TRIMETHYLAMINE (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to quantify emissions of Trimethylamine (TMA). It determines ...
Read MoreOkt 1, 1996 ... Source Test Procedure ST-22 TRIMETHYLAMINE (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to quantify emissions of Trimethylamine (TMA). It determines ...
Set 27, 1996 ... Source Test Method ST-8 DIMETHYLSULFIDE (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to determine emissions of dimethylsulfide (DMS). It is applicable ...
Read MoreSet 27, 1996 ... Source Test Method ST-8 DIMETHYLSULFIDE (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to determine emissions of dimethylsulfide (DMS). It is applicable ...
May 26, 2021 ... City of Milpitas from Landfill ...
Read MoreMay 26, 2021 ... City of Milpitas from Landfill ...
Okt 1, 1996 ... Source Test Procedure ST-32 ETHANOL, INTEGRATED SAMPLING (Adopted December 21, 1988) REF: Regulation 8, Rule 42 1. APPLICABILITY 1.1 This procedure is used to quantify emissions of ethanol. It ...
Read MoreOkt 1, 1996 ... Source Test Procedure ST-32 ETHANOL, INTEGRATED SAMPLING (Adopted December 21, 1988) REF: Regulation 8, Rule 42 1. APPLICABILITY 1.1 This procedure is used to quantify emissions of ethanol. It ...
Set 27, 1996 ... Source Test Method ST-11 MERCAPTANS Adopted (January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to determine emissions of mercaptans. It is applicable to the ...
Read MoreSet 27, 1996 ... Source Test Method ST-11 MERCAPTANS Adopted (January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to determine emissions of mercaptans. It is applicable to the ...
Set 27, 1996 ... Source Test Procedure ST-14 OXYGEN, CONTINUOUS SAMPLING Adopted January 20, 1982 REF: Regulations 9-3-301, 9-3-302 1. APPLICABILITY 1.1 This method is used to quantify emissions of oxygen. It ...
Read MoreSet 27, 1996 ... Source Test Procedure ST-14 OXYGEN, CONTINUOUS SAMPLING Adopted January 20, 1982 REF: Regulations 9-3-301, 9-3-302 1. APPLICABILITY 1.1 This method is used to quantify emissions of oxygen. It ...
Okt 1, 1996 ... Source Test Procedure ST-25 FLUORIDE, INTEGRATED SAMPLE (Adopted January 20, 1982) REF: Regulation 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of fluoride. It ...
Read MoreOkt 1, 1996 ... Source Test Procedure ST-25 FLUORIDE, INTEGRATED SAMPLE (Adopted January 20, 1982) REF: Regulation 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of fluoride. It ...
Set 27, 1996 ... Source Test Method ST-15 PARTICULATE (Adopted January 20, 1982) REF: Regulations 6-310, 6-311, 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify particulate emissions. It ...
Read MoreSet 27, 1996 ... Source Test Method ST-15 PARTICULATE (Adopted January 20, 1982) REF: Regulations 6-310, 6-311, 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify particulate emissions. It ...
Set 27, 1996 ... Source Test Procedure ST-9 LEAD Adopted (January 20, 1982) REF: Regulation, 11-1-301 1. APPLICABILITY 1.1 This procedure is used to quantify emissions of Lead. It determines compliance with ...
Read MoreSet 27, 1996 ... Source Test Procedure ST-9 LEAD Adopted (January 20, 1982) REF: Regulation, 11-1-301 1. APPLICABILITY 1.1 This procedure is used to quantify emissions of Lead. It determines compliance with ...
Set 26, 1996 ... Source Test Procedure ST-1B AMMONIA INTEGRATED SAMPLING (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to quantify emissions of ammonia. It ...
Read MoreSet 26, 1996 ... Source Test Procedure ST-1B AMMONIA INTEGRATED SAMPLING (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to quantify emissions of ammonia. It ...
May 6, 2016 ... MOP Vol. IX Procedure – P‐1 Volatile Organic Compounds Water Sampling PROCEDURE - 1 ORGANIC COMPOUNDS WATER SAMPLING REF: Regulation 11-10 1. APPLICABILITY 1.1 This procedure is used to ...
Read MoreMay 6, 2016 ... MOP Vol. IX Procedure – P‐1 Volatile Organic Compounds Water Sampling PROCEDURE - 1 ORGANIC COMPOUNDS WATER SAMPLING REF: Regulation 11-10 1. APPLICABILITY 1.1 This procedure is used to ...
Okt 1, 1996 ... Source Test Procedure ST-28 HYDROGEN SULFIDE, INTEGRATED SAMPLING (Adopted January 20, 1982) REF. Regulation 10-8-303 1. APPLICABILITY 1.1 This method is applicable for the determination of hydrogen ...
Read MoreOkt 1, 1996 ... Source Test Procedure ST-28 HYDROGEN SULFIDE, INTEGRATED SAMPLING (Adopted January 20, 1982) REF. Regulation 10-8-303 1. APPLICABILITY 1.1 This method is applicable for the determination of hydrogen ...
Oct 1, 1996 ... Source Test Procedure ST-21 TOTAL REDUCED SULFUR REF: Regulations 12-1-301 thru 303 1. APPLICABILITY 1.1 This method is used to quantify emissions of total reduced sulfur compounds (TRS) as H S, in ...
Read MoreOct 1, 1996 ... Source Test Procedure ST-21 TOTAL REDUCED SULFUR REF: Regulations 12-1-301 thru 303 1. APPLICABILITY 1.1 This method is used to quantify emissions of total reduced sulfur compounds (TRS) as H S, in ...
Set 27, 1996 ... Source Test Procedure ST-5 CARBON DIOXIDE, CONTINUOUS SAMPLING REF: Regulation 6-310.1 1. APPLICABILITY 1.1 This method is used to quantify emissions of carbon dioxide. It determines compliance ...
Read MoreSet 27, 1996 ... Source Test Procedure ST-5 CARBON DIOXIDE, CONTINUOUS SAMPLING REF: Regulation 6-310.1 1. APPLICABILITY 1.1 This method is used to quantify emissions of carbon dioxide. It determines compliance ...
Oct 10, 2017 ... October 10, 2017 Request for Qualifications #2017-015 Air Sampling Network Maintenance and Operations SECTION I – SUMMARY ...
Read MoreOct 10, 2017 ... October 10, 2017 Request for Qualifications #2017-015 Air Sampling Network Maintenance and Operations SECTION I – SUMMARY ...
Set 27, 1996 ... SOURCE TEST PROCEDURE ST-7 ORGANIC COMPOUNDS REF: Regulation 8 1. APPLICABILITY 1.1 This procedure is used to quantify emissions of organic compounds. It is applicable to the determination of ...
Read MoreSet 27, 1996 ... SOURCE TEST PROCEDURE ST-7 ORGANIC COMPOUNDS REF: Regulation 8 1. APPLICABILITY 1.1 This procedure is used to quantify emissions of organic compounds. It is applicable to the determination of ...
Peb 2, 2021 ... February 3, 2021 Request for Qualifications# 2020-001 Air Sampling Network Maintenance and Operations SECTION I – SUMMARY ...
Read MorePeb 2, 2021 ... February 3, 2021 Request for Qualifications# 2020-001 Air Sampling Network Maintenance and Operations SECTION I – SUMMARY ...
Mar 16, 2016 ... MOP Vol. IX Procedure - 1 Volatile Organic Compounds Water Sampling PROCEDURE - 1 ORGANIC COMPOUNDS WATER SAMPLING REF: Regulation 11-10 1. APPLICABILITY 1.1 This procedure is used to ...
Read MoreMar 16, 2016 ... MOP Vol. IX Procedure - 1 Volatile Organic Compounds Water Sampling PROCEDURE - 1 ORGANIC COMPOUNDS WATER SAMPLING REF: Regulation 11-10 1. APPLICABILITY 1.1 This procedure is used to ...
Huling Isinapanahon: 11/8/2016