火炬

BAAQMD Refinery Flare Emission Report
Report Settings
Tesoro Martinez - Ammonia Plant
Download CSV
一月 - 2018
Date Vent Gas Flow Methane NMHC Sulfur Dioxide
(mo/day/yr) (volume in scf) See note **** (lbs) (lbs) (lbs)
1/1/2018 29,711.00 0.00 0.00 0.10
1/2/2018 35,248.00 0.00 0.00 0.15
1/3/2018 51,118.00 0.00 0.00 0.14
1/4/2018 30,602.00 0.00 0.00 0.09
1/5/2018 29,559.00 0.00 0.00 0.07
1/6/2018 9,950.00 0.00 0.00 0.08
1/7/2018 45,052.00 0.00 0.00 0.09
1/8/2018 40,311.00 0.00 0.00 0.11
1/9/2018 30,984.00 0.00 0.00 0.11
1/10/2018 55,227.00 0.00 0.00 0.13
1/11/2018 51,146.00 0.00 0.00 0.13
1/12/2018 25,963.00 0.00 0.00 0.11
1/13/2018 25,405.00 0.00 0.00 0.11
1/14/2018 48,406.00 0.00 0.00 0.09
1/15/2018 62,741.00 0.00 0.00 0.10
1/16/2018 39,626.00 0.00 0.00 0.11
1/17/2018 32,730.00 0.00 0.00 0.11
1/18/2018 17,279.00 0.00 0.00 0.09
1/19/2018 30,285.00 0.00 0.00 0.10
1/20/2018 39,714.00 0.00 0.00 0.10
1/21/2018 25,898.00 0.00 0.00 0.10
1/22/2018 25,778.00 0.00 0.00 0.12
1/23/2018 29,937.00 0.00 0.00 0.13
1/24/2018 49,540.00 0.00 0.00 0.16
1/25/2018 29,361.00 0.00 0.00 0.15
1/26/2018 18,170.00 0.00 0.00 0.14
1/27/2018 9,462.00 0.00 0.00 0.11
1/28/2018 10,285.00 0.00 0.00 0.09
1/29/2018 14,919.00 0.00 0.00 0.09
1/30/2018 11,000.00 0.00 0.00 0.12
1/31/2018 8,085.00 0.00 0.00 0.14
一月 Totals 963,492.00 0.00 0.00 3.47
  • * Natural gas is used for both pilot and purge gas for the refinery flare system, except for the Emergency Flare that uses nitrogen as purge gas.
    The flow is determined using an orifice calculation based on the orifice size in the lines and the line pressure upstream of the orifice.
    ** The purge gas and pilot gas flows at the Ammonia Plant flare are measured by rotameters in the natural
    gas and nitrogen lines.
    *** The purge gas and pilot gas flows at the 50 Unit flare are measured by flow meters
    **** Corrected for seal pot level and pressure data
    ***** 50 Unit change in flare purge gas to nitrogen
    In the case of an invalid sample, the monthly average was used for composition data
Tesoro Martinez Ammonia Plant Flare Report 1/1/2018 - 1/31/2018
 
 

Contact Us


一般資訊

415 749-4900


空氣監測

415 749-4985

Contact Us

Spare the Air Status

Last Updated: 2023/8/3