|
133 results for 'sampling sampling'
Search: 'sampling sampling'
133 Search:
Oct 1, 1996 ... Source Test Procedure ST-22 TRIMETHYLAMINE (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to quantify emissions of Trimethylamine (TMA). It determines ...
Read MoreOct 1, 1996 ... Source Test Procedure ST-22 TRIMETHYLAMINE (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to quantify emissions of Trimethylamine (TMA). It determines ...
Sep 27, 1996 ... Source Test Procedure ST-10 MERCURY Adopted (January 20, 1982) REF: Regulation 11-5-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of gaseous and particulate mercury. It ...
Read MoreSep 27, 1996 ... Source Test Procedure ST-10 MERCURY Adopted (January 20, 1982) REF: Regulation 11-5-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of gaseous and particulate mercury. It ...
Sep 27, 1996 ... Source Test Method ST-8 DIMETHYLSULFIDE (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to determine emissions of dimethylsulfide (DMS). It is applicable ...
Read MoreSep 27, 1996 ... Source Test Method ST-8 DIMETHYLSULFIDE (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to determine emissions of dimethylsulfide (DMS). It is applicable ...
Sep 27, 1996 ... Source Test Method ST-15 PARTICULATE (Adopted January 20, 1982) REF: Regulations 6-310, 6-311, 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify particulate emissions. It ...
Read MoreSep 27, 1996 ... Source Test Method ST-15 PARTICULATE (Adopted January 20, 1982) REF: Regulations 6-310, 6-311, 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify particulate emissions. It ...
Oct 1, 1996 ... Source Test Procedure ST-25 FLUORIDE, INTEGRATED SAMPLE (Adopted January 20, 1982) REF: Regulation 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of fluoride. It ...
Read MoreOct 1, 1996 ... Source Test Procedure ST-25 FLUORIDE, INTEGRATED SAMPLE (Adopted January 20, 1982) REF: Regulation 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of fluoride. It ...
Sep 27, 1996 ... Source Test Procedure ST-14 OXYGEN, CONTINUOUS SAMPLING Adopted January 20, 1982 REF: Regulations 9-3-301, 9-3-302 1. APPLICABILITY 1.1 This method is used to quantify emissions of oxygen. It ...
Read MoreSep 27, 1996 ... Source Test Procedure ST-14 OXYGEN, CONTINUOUS SAMPLING Adopted January 20, 1982 REF: Regulations 9-3-301, 9-3-302 1. APPLICABILITY 1.1 This method is used to quantify emissions of oxygen. It ...
Sep 27, 1996 ... Source Test Procedure ST-9 LEAD Adopted (January 20, 1982) REF: Regulation, 11-1-301 1. APPLICABILITY 1.1 This procedure is used to quantify emissions of Lead. It determines compliance with ...
Read MoreSep 27, 1996 ... Source Test Procedure ST-9 LEAD Adopted (January 20, 1982) REF: Regulation, 11-1-301 1. APPLICABILITY 1.1 This procedure is used to quantify emissions of Lead. It determines compliance with ...
Sep 26, 1996 ... Source Test Procedure ST-1B AMMONIA INTEGRATED SAMPLING (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to quantify emissions of ammonia. It ...
Read MoreSep 26, 1996 ... Source Test Procedure ST-1B AMMONIA INTEGRATED SAMPLING (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to quantify emissions of ammonia. It ...
May 6, 2016 ... MOP Vol. IX Procedure – P‐1 Volatile Organic Compounds Water Sampling PROCEDURE - 1 ORGANIC COMPOUNDS WATER SAMPLING REF: Regulation 11-10 1. APPLICABILITY 1.1 This procedure is used to ...
Read MoreMay 6, 2016 ... MOP Vol. IX Procedure – P‐1 Volatile Organic Compounds Water Sampling PROCEDURE - 1 ORGANIC COMPOUNDS WATER SAMPLING REF: Regulation 11-10 1. APPLICABILITY 1.1 This procedure is used to ...
Sep 27, 1996 ... Source Test Procedure ST-5 CARBON DIOXIDE, CONTINUOUS SAMPLING REF: Regulation 6-310.1 1. APPLICABILITY 1.1 This method is used to quantify emissions of carbon dioxide. It determines compliance ...
Read MoreSep 27, 1996 ... Source Test Procedure ST-5 CARBON DIOXIDE, CONTINUOUS SAMPLING REF: Regulation 6-310.1 1. APPLICABILITY 1.1 This method is used to quantify emissions of carbon dioxide. It determines compliance ...
Oct 1, 1996 ... Source Test Procedure ST-28 HYDROGEN SULFIDE, INTEGRATED SAMPLING (Adopted January 20, 1982) REF. Regulation 10-8-303 1. APPLICABILITY 1.1 This method is applicable for the determination of hydrogen ...
Read MoreOct 1, 1996 ... Source Test Procedure ST-28 HYDROGEN SULFIDE, INTEGRATED SAMPLING (Adopted January 20, 1982) REF. Regulation 10-8-303 1. APPLICABILITY 1.1 This method is applicable for the determination of hydrogen ...
Oct 1, 1996 ... Source Test Procedure ST-21 TOTAL REDUCED SULFUR REF: Regulations 12-1-301 thru 303 1. APPLICABILITY 1.1 This method is used to quantify emissions of total reduced sulfur compounds (TRS) as H S, in ...
Read MoreOct 1, 1996 ... Source Test Procedure ST-21 TOTAL REDUCED SULFUR REF: Regulations 12-1-301 thru 303 1. APPLICABILITY 1.1 This method is used to quantify emissions of total reduced sulfur compounds (TRS) as H S, in ...
May 10, 2023 ... May 10, 2023 Request for Qualifications# 2023-030 Air Sampling Network Maintenance and Operations SECTION I – SUMMARY ...
Read MoreMay 10, 2023 ... May 10, 2023 Request for Qualifications# 2023-030 Air Sampling Network Maintenance and Operations SECTION I – SUMMARY ...
Feb 2, 2021 ... February 3, 2021 Request for Qualifications# 2020-001 Air Sampling Network Maintenance and Operations SECTION I – SUMMARY ...
Read MoreFeb 2, 2021 ... February 3, 2021 Request for Qualifications# 2020-001 Air Sampling Network Maintenance and Operations SECTION I – SUMMARY ...
Sep 27, 1996 ... Source Test Procedure ST-19A SULFUR DIOXIDE, CONTINUOUS SAMPLING (Adopted January 20, 1982) REF: Regulations 9-1-302, 9-1-304 through 310, 10-1-301 1. APPLICABILITY 1.1 This method is used to ...
Read MoreSep 27, 1996 ... Source Test Procedure ST-19A SULFUR DIOXIDE, CONTINUOUS SAMPLING (Adopted January 20, 1982) REF: Regulations 9-1-302, 9-1-304 through 310, 10-1-301 1. APPLICABILITY 1.1 This method is used to ...
Sep 27, 1996 ... Source Test Procedure ST-13A OXIDES OF NITROGEN, CONTINUOUS SAMPLING REF: Regulations 9-3-301, 9-3-302, 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of oxides of nitrogen.
Read MoreSep 27, 1996 ... Source Test Procedure ST-13A OXIDES OF NITROGEN, CONTINUOUS SAMPLING REF: Regulations 9-3-301, 9-3-302, 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of oxides of nitrogen.
Sep 27, 1996 ... Source Test Procedure ST-19B TOTAL SULFUR OXIDES, INTEGRATED SAMPLE REF: Regulations 9-1-302, 9-1-304 through 310, 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of total ...
Read MoreSep 27, 1996 ... Source Test Procedure ST-19B TOTAL SULFUR OXIDES, INTEGRATED SAMPLE REF: Regulations 9-1-302, 9-1-304 through 310, 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of total ...
Aug 11, 2023 ... South Bay Odor Attribution Study Final Report 230407112709_08bfbc6e Bay Area Air Quality Management District Document Title B a y A r e a A i r Q u a l i t y M a n a g ...
Read MoreAug 11, 2023 ... South Bay Odor Attribution Study Final Report 230407112709_08bfbc6e Bay Area Air Quality Management District Document Title B a y A r e a A i r Q u a l i t y M a n a g ...
Sep 9, 2010 ... West Oakland Monitoring Study DRAFT REPORT APPENDICES Sampling and Analytical Methods Prepared for: Bay Area Air Quality Management District 939 Ellis Street ...
Read MoreSep 9, 2010 ... West Oakland Monitoring Study DRAFT REPORT APPENDICES Sampling and Analytical Methods Prepared for: Bay Area Air Quality Management District 939 Ellis Street ...
上次更新: 2016/11/8