十月 1, 1996 ... Source Test Procedure ST-23 WATER VAPOR (Adopted January 20, 1982) 1. APPLICABILITY 1.1 This method is used to quantify the water vapor content of stack gases. It is applicable in all cases in which ...
Read More十月 1, 1996 ... Source Test Procedure ST-23 WATER VAPOR (Adopted January 20, 1982) 1. APPLICABILITY 1.1 This method is used to quantify the water vapor content of stack gases. It is applicable in all cases in which ...
一月 18, 2018 ... Sampling Study Protocol Specifications for Third-Party Verifiers Fugitive Emissions from Petroleum Refinery Equipment in Heavy Liquid Service Joint Study between the Bay Area Air ...
Read More一月 18, 2018 ... Sampling Study Protocol Specifications for Third-Party Verifiers Fugitive Emissions from Petroleum Refinery Equipment in Heavy Liquid Service Joint Study between the Bay Area Air ...
十月 1, 1996 ... Source Test Procedure ST-22 TRIMETHYLAMINE (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to quantify emissions of Trimethylamine (TMA). It determines ...
Read More十月 1, 1996 ... Source Test Procedure ST-22 TRIMETHYLAMINE (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to quantify emissions of Trimethylamine (TMA). It determines ...
May 26, 2021 ... City of Milpitas from Landfill ...
Read MoreMay 26, 2021 ... City of Milpitas from Landfill ...
五月 6, 2016 ... MOP Vol. IX Procedure – P‐1 Volatile Organic Compounds Water Sampling PROCEDURE - 1 ORGANIC COMPOUNDS WATER SAMPLING REF: Regulation 11-10 1. APPLICABILITY 1.1 This procedure is used to ...
Read More五月 6, 2016 ... MOP Vol. IX Procedure – P‐1 Volatile Organic Compounds Water Sampling PROCEDURE - 1 ORGANIC COMPOUNDS WATER SAMPLING REF: Regulation 11-10 1. APPLICABILITY 1.1 This procedure is used to ...
十月 1, 1996 ... Source Test Procedure ST-25 FLUORIDE, INTEGRATED SAMPLE (Adopted January 20, 1982) REF: Regulation 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of fluoride. It ...
Read More十月 1, 1996 ... Source Test Procedure ST-25 FLUORIDE, INTEGRATED SAMPLE (Adopted January 20, 1982) REF: Regulation 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of fluoride. It ...
九月 27, 1996 ... Source Test Method ST-15 PARTICULATE (Adopted January 20, 1982) REF: Regulations 6-310, 6-311, 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify particulate emissions. It ...
Read More九月 27, 1996 ... Source Test Method ST-15 PARTICULATE (Adopted January 20, 1982) REF: Regulations 6-310, 6-311, 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify particulate emissions. It ...
九月 27, 1996 ... Source Test Procedure ST-5 CARBON DIOXIDE, CONTINUOUS SAMPLING REF: Regulation 6-310.1 1. APPLICABILITY 1.1 This method is used to quantify emissions of carbon dioxide. It determines compliance ...
Read More九月 27, 1996 ... Source Test Procedure ST-5 CARBON DIOXIDE, CONTINUOUS SAMPLING REF: Regulation 6-310.1 1. APPLICABILITY 1.1 This method is used to quantify emissions of carbon dioxide. It determines compliance ...
十月 10, 2017 ... October 10, 2017 Request for Qualifications #2017-015 Air Sampling Network Maintenance and Operations SECTION I – SUMMARY ...
Read More十月 10, 2017 ... October 10, 2017 Request for Qualifications #2017-015 Air Sampling Network Maintenance and Operations SECTION I – SUMMARY ...
Mar 16, 2016 ... MOP Vol. IX Procedure - 1 Volatile Organic Compounds Water Sampling PROCEDURE - 1 ORGANIC COMPOUNDS WATER SAMPLING REF: Regulation 11-10 1. APPLICABILITY 1.1 This procedure is used to ...
Read MoreMar 16, 2016 ... MOP Vol. IX Procedure - 1 Volatile Organic Compounds Water Sampling PROCEDURE - 1 ORGANIC COMPOUNDS WATER SAMPLING REF: Regulation 11-10 1. APPLICABILITY 1.1 This procedure is used to ...
九月 27, 1996 ... Source Test Procedure ST-6 CARBON MONOXIDE, CONTINUOUS SAMPLING REF: Regulation 8-1-110.3, 10-8-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of carbon monoxide (CO).
Read More九月 27, 1996 ... Source Test Procedure ST-6 CARBON MONOXIDE, CONTINUOUS SAMPLING REF: Regulation 8-1-110.3, 10-8-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of carbon monoxide (CO).
九月 27, 1996 ... Source Test Procedure ST-19A SULFUR DIOXIDE, CONTINUOUS SAMPLING (Adopted January 20, 1982) REF: Regulations 9-1-302, 9-1-304 through 310, 10-1-301 1. APPLICABILITY 1.1 This method is used to ...
Read More九月 27, 1996 ... Source Test Procedure ST-19A SULFUR DIOXIDE, CONTINUOUS SAMPLING (Adopted January 20, 1982) REF: Regulations 9-1-302, 9-1-304 through 310, 10-1-301 1. APPLICABILITY 1.1 This method is used to ...
九月 27, 1996 ... SOURCE TEST PROCEDURE ST-7 ORGANIC COMPOUNDS REF: Regulation 8 1. APPLICABILITY 1.1 This procedure is used to quantify emissions of organic compounds. It is applicable to the determination of ...
Read More九月 27, 1996 ... SOURCE TEST PROCEDURE ST-7 ORGANIC COMPOUNDS REF: Regulation 8 1. APPLICABILITY 1.1 This procedure is used to quantify emissions of organic compounds. It is applicable to the determination of ...
十月 1, 1996 ... Source Test Procedure ST-24 TANK SAMPLING FOR ORSAT ANALYSIS (CO, CO , O ) 2 2 REF: Regulations 6-310.1, 8-1-110.3, 10-3-301, 9-3-301 through 9-3-304 1. APPLICABILITY 1.1 This procedure is used to ...
Read More十月 1, 1996 ... Source Test Procedure ST-24 TANK SAMPLING FOR ORSAT ANALYSIS (CO, CO , O ) 2 2 REF: Regulations 6-310.1, 8-1-110.3, 10-3-301, 9-3-301 through 9-3-304 1. APPLICABILITY 1.1 This procedure is used to ...
Aug 11, 2023 ... South Bay Odor Attribution Study Final Report 230407112709_08bfbc6e Bay Area Air Quality Management District Document Title B a y A r e a A i r Q u a l i t y M a n a g ...
Read MoreAug 11, 2023 ... South Bay Odor Attribution Study Final Report 230407112709_08bfbc6e Bay Area Air Quality Management District Document Title B a y A r e a A i r Q u a l i t y M a n a g ...
八月 27, 2013 ... Guidelines for Construction of Particulate Sampling and Testing Facilities Introduction Selection of a proper sampling site is vital to assure representative measurement of pollutant ...
Read More八月 27, 2013 ... Guidelines for Construction of Particulate Sampling and Testing Facilities Introduction Selection of a proper sampling site is vital to assure representative measurement of pollutant ...
十月 1, 1996 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Manual of Procedures Volume IV Source Test Policy and ...
Read More十月 1, 1996 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Manual of Procedures Volume IV Source Test Policy and ...
May 21, 2012 ... Facility Name: SFPP. L.P. San Jose Terminal #: A4020 Permit for Facility Page #l through April 30,2012 Report for Period November 1,201l Title V Monitoring Verifìcation Semi-Annual Table VII - ...
Read MoreMay 21, 2012 ... Facility Name: SFPP. L.P. San Jose Terminal #: A4020 Permit for Facility Page #l through April 30,2012 Report for Period November 1,201l Title V Monitoring Verifìcation Semi-Annual Table VII - ...
Jun 1, 2022 ... Compliance Advisory June 9, 2022 Source Testing and Emissions Monitoring Advisory This Compliance Advisory is provided to inform you about activities of the Air District which may affect your ...
Read MoreJun 1, 2022 ... Compliance Advisory June 9, 2022 Source Testing and Emissions Monitoring Advisory This Compliance Advisory is provided to inform you about activities of the Air District which may affect your ...