搜尋

  • BACT / TBACT 工作簿
    BACT / TBACT 工作簿

    查看 BACT/TBACT 工作簿(在新污染源審查許可過程中為許可申請者和空氣局工作人員提供指導的資源)。

    Read More

    查看 BACT/TBACT 工作簿(在新污染源審查許可過程中為許可申請者和空氣局工作人員提供指導的資源)。

  • BACTDetUpd
    BACTDetUpd

    Mar 13, 2008 ... Procedure: New or Updated BACT Determinations Introduction This procedure identifies the main participants and the procedures for making a BACT determination and updating the BACT/TBACT ...

    Read More
    (56 Kb PDF, 7 pgs)

    Mar 13, 2008 ... Procedure: New or Updated BACT Determinations Introduction This procedure identifies the main participants and the procedures for making a BACT determination and updating the BACT/TBACT ...

  • INTRODUCTION
    INTRODUCTION

    Mar 19, 2014 ... Last Updated 2002 INTRODUCTION The Bay Area Air Quality Management District's New Source Review Rule, Regulation 2, Rule 2, and the District's Air Toxics Risk Management Policy require that new or ...

    Read More
    (88 Kb PDF, 3 pgs)

    Mar 19, 2014 ... Last Updated 2002 INTRODUCTION The Bay Area Air Quality Management District's New Source Review Rule, Regulation 2, Rule 2, and the District's Air Toxics Risk Management Policy require that new or ...

  • User Guide
    User Guide

    三月 12, 2014 ... USER'S GUIDE TO BACT/TBACT WORKBOOK The BACT and TBACT determinations listed in this workbook are grouped by source category, either industrial equipment or process category, and compiled in the ...

    Read More
    (84 Kb PDF, 2 pgs)

    三月 12, 2014 ... USER'S GUIDE TO BACT/TBACT WORKBOOK The BACT and TBACT determinations listed in this workbook are grouped by source category, either industrial equipment or process category, and compiled in the ...

  • 688819 Permit Evaluation
    688819 Permit Evaluation

    七月 9, 2024 ... ENGINEERING EVALUATION Facility ID No. 203332 US EPA - Hayward 23217 Kidder Street, Hayward, CA 94545 Application No. 688819 Background US EPA – Hayward is applying for an Authority to ...

    Read More
    (297 Kb PDF, 9 pgs)

    七月 9, 2024 ... ENGINEERING EVALUATION Facility ID No. 203332 US EPA - Hayward 23217 Kidder Street, Hayward, CA 94545 Application No. 688819 Background US EPA – Hayward is applying for an Authority to ...

  • 706878 Permit Evaluation
    706878 Permit Evaluation

    Nov 12, 2024 ... ENGINEERING EVALUATION Facility ID No. 16059 Visa USA, Inc. 901 Metro Center, Foster City, CA 94404 Application No. 706878 Background Visa USA, Inc. is applying for an Authority to ...

    Read More
    (307 Kb PDF, 9 pgs)

    Nov 12, 2024 ... ENGINEERING EVALUATION Facility ID No. 16059 Visa USA, Inc. 901 Metro Center, Foster City, CA 94404 Application No. 706878 Background Visa USA, Inc. is applying for an Authority to ...

  • 691776 Permit Evaluation
    691776 Permit Evaluation

    Jul 10, 2024 ... DRAFT ENGINEERING EVALUATION Facility ID No. 203365 Fidelity Information Services, LLC 501 Canal Boulevard, Richmond, CA 94804 Application No. 691776 Background Fidelity Information ...

    Read More
    (355 Kb PDF, 10 pgs)

    Jul 10, 2024 ... DRAFT ENGINEERING EVALUATION Facility ID No. 203365 Fidelity Information Services, LLC 501 Canal Boulevard, Richmond, CA 94804 Application No. 691776 Background Fidelity Information ...

  • 694612 Permit Evaluation
    694612 Permit Evaluation

    Aug 2, 2024 ... DRAFT ENGINEERING EVALUATION Facility ID No. 203405 Phoenix 801 Pine, LP 811 Pine Street, Oakland, CA 94607 Application No. 694612 Background Phoenix 801 Pine, LP is applying for an ...

    Read More
    (359 Kb PDF, 9 pgs)

    Aug 2, 2024 ... DRAFT ENGINEERING EVALUATION Facility ID No. 203405 Phoenix 801 Pine, LP 811 Pine Street, Oakland, CA 94607 Application No. 694612 Background Phoenix 801 Pine, LP is applying for an ...

  • 689782 Permit Evaluation
    689782 Permit Evaluation

    六月 14, 2024 ... DRAFT ENGINEERING EVALUATION Facility ID No. 14064 Central Contra Costa Sanitary District - Maltby Pump Station 990 Central Avenue, Martinez, CA 94553 Application No. 689782 Background ...

    Read More
    (328 Kb PDF, 12 pgs)

    六月 14, 2024 ... DRAFT ENGINEERING EVALUATION Facility ID No. 14064 Central Contra Costa Sanitary District - Maltby Pump Station 990 Central Avenue, Martinez, CA 94553 Application No. 689782 Background ...

  • 673547 Permit Evaluation
    673547 Permit Evaluation

    Sep 26, 2023 ... ENGINEERING EVALUATION Facility ID No. 202934 Edison Technology Park, MP, LP 3475 Edison Way, Menlo Park, CA 94025 Application No. 673547 Background Edison Technology Park, MP, LP is ...

    Read More
    (240 Kb PDF, 9 pgs)

    Sep 26, 2023 ... ENGINEERING EVALUATION Facility ID No. 202934 Edison Technology Park, MP, LP 3475 Edison Way, Menlo Park, CA 94025 Application No. 673547 Background Edison Technology Park, MP, LP is ...

  • 682764 Permit Evaluation
    682764 Permit Evaluation

    九月 24, 2024 ... ENGINEERING EVALUATION Facility ID No. 203208 Breakthru Beverage California LLC dba Wine Warehouse 912 Harbour Way South, Richmond, CA 94804 Application No. 682764 Background Breakthru ...

    Read More
    (276 Kb PDF, 10 pgs)

    九月 24, 2024 ... ENGINEERING EVALUATION Facility ID No. 203208 Breakthru Beverage California LLC dba Wine Warehouse 912 Harbour Way South, Richmond, CA 94804 Application No. 682764 Background Breakthru ...

  • 696353 Permit Evaluation
    696353 Permit Evaluation

    Nov 14, 2024 ... ENGINEERING EVALUATION Facility ID No. 203399 WRTH 5555 Giant Highway, Richmond, CA 94806 Application No. 696353 Background WRTH, is applying for an Authority to Construct/Permit to ...

    Read More
    (228 Kb PDF, 8 pgs)

    Nov 14, 2024 ... ENGINEERING EVALUATION Facility ID No. 203399 WRTH 5555 Giant Highway, Richmond, CA 94806 Application No. 696353 Background WRTH, is applying for an Authority to Construct/Permit to ...

  • 710902 Permit Evaluation
    710902 Permit Evaluation

    Nov 8, 2024 ... ENGINEERING EVALUATION Facility ID No. 203634 Prologis Nexus 1345 Doolittle Drive, San Leandro, CA 94577 Application No. 710902 Background Prologis Nexus is applying for an Authority to ...

    Read More
    (337 Kb PDF, 11 pgs)

    Nov 8, 2024 ... ENGINEERING EVALUATION Facility ID No. 203634 Prologis Nexus 1345 Doolittle Drive, San Leandro, CA 94577 Application No. 710902 Background Prologis Nexus is applying for an Authority to ...

  • 690408 Permit Evaluation
    690408 Permit Evaluation

    Nov 12, 2024 ... ENGINEERING EVALUATION Facility ID No. 203360 2275 Bayshore 2275 East Bayshore Road, Palo Alto, CA 94303 Application No. 690408 Background 2275 Bayshore is applying for an Authority to ...

    Read More
    (341 Kb PDF, 11 pgs)

    Nov 12, 2024 ... ENGINEERING EVALUATION Facility ID No. 203360 2275 Bayshore 2275 East Bayshore Road, Palo Alto, CA 94303 Application No. 690408 Background 2275 Bayshore is applying for an Authority to ...

  • Presentation
    Presentation

    Oct 21, 2024 ... Best Available Control Technology (BACT) and BACT for Toxics (TBACT) for Small to Medium Sized Standby Diesel Engines October 21, ...

    Read More
    (807 Kb PDF, 27 pgs)

    Oct 21, 2024 ... Best Available Control Technology (BACT) and BACT for Toxics (TBACT) for Small to Medium Sized Standby Diesel Engines October 21, ...

  • 689792 Permit Evaluation
    689792 Permit Evaluation

    九月 17, 2024 ... ENGINEERING EVALUATION Facility ID No. 14060 Central Contra Costa Sanitary District 2001 Marina Vista, Martinez, CA 94553 Application No. 689792 Background Central Contra Costa Sanitary ...

    Read More
    (282 Kb PDF, 10 pgs)

    九月 17, 2024 ... ENGINEERING EVALUATION Facility ID No. 14060 Central Contra Costa Sanitary District 2001 Marina Vista, Martinez, CA 94553 Application No. 689792 Background Central Contra Costa Sanitary ...

  • Definition of BACT TBACT
    Definition of BACT TBACT

    Mar 19, 2014 ... Last Updated 2002 DEFINITION OF BACT AND TBACT District Regulation 2, Rule 2, Section 206 defines Best Available Control Technology as follows: 2-2-206 Best Available Control Technology (BACT): ...

    Read More
    (83 Kb PDF, 2 pgs)

    Mar 19, 2014 ... Last Updated 2002 DEFINITION OF BACT AND TBACT District Regulation 2, Rule 2, Section 206 defines Best Available Control Technology as follows: 2-2-206 Best Available Control Technology (BACT): ...

  • 710255 Permit Evaluation
    710255 Permit Evaluation

    十一月 4, 2024 ... Facility ID: 203617 Application #710255 ENGINEERING EVALUATION Facility ID: 203617 Aegis Gardens Fremont 36281 Fremont Blvd, Fremont, CA 94536 Application #710255 Background Aegis ...

    Read More
    (329 Kb PDF, 10 pgs)

    十一月 4, 2024 ... Facility ID: 203617 Application #710255 ENGINEERING EVALUATION Facility ID: 203617 Aegis Gardens Fremont 36281 Fremont Blvd, Fremont, CA 94536 Application #710255 Background Aegis ...

  • 698013 Permit Evaluation
    698013 Permit Evaluation

    七月 23, 2024 ... ENGINEERING EVALUATION Facility ID No. 203445 Valley Surgical Suites 3365 Solano Avenue, Napa, CA 94558 Application No. 698013 Background Valley Surgical Suites is applying for an ...

    Read More
    (281 Kb PDF, 11 pgs)

    七月 23, 2024 ... ENGINEERING EVALUATION Facility ID No. 203445 Valley Surgical Suites 3365 Solano Avenue, Napa, CA 94558 Application No. 698013 Background Valley Surgical Suites is applying for an ...

  • Cost Effectiveness Calculations NOx
    Cost Effectiveness Calculations NOx

    Mar 19, 2014 ... EXAMPLE COST-EFFECTIVENESS CALCULATIONS FOR NO CONTROLS x The following pages provide example calculations for determining the cost-effectiveness of NO x control options for steam generating ...

    Read More
    (95 Kb PDF, 3 pgs)

    Mar 19, 2014 ... EXAMPLE COST-EFFECTIVENESS CALCULATIONS FOR NO CONTROLS x The following pages provide example calculations for determining the cost-effectiveness of NO x control options for steam generating ...

Spare the Air Status

上次更新: 2016/11/8