132 results for 'sampling sampling'
Search: 'sampling sampling'
132 Search:
Oct 1, 1996 ... Source Test Procedure ST-23 WATER VAPOR (Adopted January 20, 1982) 1. APPLICABILITY 1.1 This method is used to quantify the water vapor content of stack gases. It is applicable in all cases in which ...
Read MoreOct 1, 1996 ... Source Test Procedure ST-23 WATER VAPOR (Adopted January 20, 1982) 1. APPLICABILITY 1.1 This method is used to quantify the water vapor content of stack gases. It is applicable in all cases in which ...
Thg1 18, 2018 ... Sampling Study Protocol Specifications for Third-Party Verifiers Fugitive Emissions from Petroleum Refinery Equipment in Heavy Liquid Service Joint Study between the Bay Area Air ...
Read MoreThg1 18, 2018 ... Sampling Study Protocol Specifications for Third-Party Verifiers Fugitive Emissions from Petroleum Refinery Equipment in Heavy Liquid Service Joint Study between the Bay Area Air ...
Sep 27, 1996 ... Source Test Method ST-8 DIMETHYLSULFIDE (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to determine emissions of dimethylsulfide (DMS). It is applicable ...
Read MoreSep 27, 1996 ... Source Test Method ST-8 DIMETHYLSULFIDE (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to determine emissions of dimethylsulfide (DMS). It is applicable ...
Thg5 6, 2016 ... MOP Vol. IX Procedure – P‐1 Volatile Organic Compounds Water Sampling PROCEDURE - 1 ORGANIC COMPOUNDS WATER SAMPLING REF: Regulation 11-10 1. APPLICABILITY 1.1 This procedure is used to ...
Read MoreThg5 6, 2016 ... MOP Vol. IX Procedure – P‐1 Volatile Organic Compounds Water Sampling PROCEDURE - 1 ORGANIC COMPOUNDS WATER SAMPLING REF: Regulation 11-10 1. APPLICABILITY 1.1 This procedure is used to ...
Sep 27, 1996 ... Source Test Procedure ST-14 OXYGEN, CONTINUOUS SAMPLING Adopted January 20, 1982 REF: Regulations 9-3-301, 9-3-302 1. APPLICABILITY 1.1 This method is used to quantify emissions of oxygen. It ...
Read MoreSep 27, 1996 ... Source Test Procedure ST-14 OXYGEN, CONTINUOUS SAMPLING Adopted January 20, 1982 REF: Regulations 9-3-301, 9-3-302 1. APPLICABILITY 1.1 This method is used to quantify emissions of oxygen. It ...
Oct 1, 1996 ... Source Test Procedure ST-25 FLUORIDE, INTEGRATED SAMPLE (Adopted January 20, 1982) REF: Regulation 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of fluoride. It ...
Read MoreOct 1, 1996 ... Source Test Procedure ST-25 FLUORIDE, INTEGRATED SAMPLE (Adopted January 20, 1982) REF: Regulation 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of fluoride. It ...
Sep 27, 1996 ... Source Test Method ST-15 PARTICULATE (Adopted January 20, 1982) REF: Regulations 6-310, 6-311, 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify particulate emissions. It ...
Read MoreSep 27, 1996 ... Source Test Method ST-15 PARTICULATE (Adopted January 20, 1982) REF: Regulations 6-310, 6-311, 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify particulate emissions. It ...
Oct 1, 1996 ... Source Test Procedure ST-28 HYDROGEN SULFIDE, INTEGRATED SAMPLING (Adopted January 20, 1982) REF. Regulation 10-8-303 1. APPLICABILITY 1.1 This method is applicable for the determination of hydrogen ...
Read MoreOct 1, 1996 ... Source Test Procedure ST-28 HYDROGEN SULFIDE, INTEGRATED SAMPLING (Adopted January 20, 1982) REF. Regulation 10-8-303 1. APPLICABILITY 1.1 This method is applicable for the determination of hydrogen ...
Sep 27, 1996 ... Source Test Procedure ST-5 CARBON DIOXIDE, CONTINUOUS SAMPLING REF: Regulation 6-310.1 1. APPLICABILITY 1.1 This method is used to quantify emissions of carbon dioxide. It determines compliance ...
Read MoreSep 27, 1996 ... Source Test Procedure ST-5 CARBON DIOXIDE, CONTINUOUS SAMPLING REF: Regulation 6-310.1 1. APPLICABILITY 1.1 This method is used to quantify emissions of carbon dioxide. It determines compliance ...
Thg5 10, 2023 ... May 10, 2023 Request for Qualifications# 2023-030 Air Sampling Network Maintenance and Operations SECTION I – SUMMARY ...
Read MoreThg5 10, 2023 ... May 10, 2023 Request for Qualifications# 2023-030 Air Sampling Network Maintenance and Operations SECTION I – SUMMARY ...
Thg10 10, 2017 ... October 10, 2017 Request for Qualifications #2017-015 Air Sampling Network Maintenance and Operations SECTION I – SUMMARY ...
Read MoreThg10 10, 2017 ... October 10, 2017 Request for Qualifications #2017-015 Air Sampling Network Maintenance and Operations SECTION I – SUMMARY ...
Sep 27, 1996 ... Source Test Procedure ST-6 CARBON MONOXIDE, CONTINUOUS SAMPLING REF: Regulation 8-1-110.3, 10-8-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of carbon monoxide (CO).
Read MoreSep 27, 1996 ... Source Test Procedure ST-6 CARBON MONOXIDE, CONTINUOUS SAMPLING REF: Regulation 8-1-110.3, 10-8-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of carbon monoxide (CO).
Sep 27, 1996 ... Source Test Procedure ST-19B TOTAL SULFUR OXIDES, INTEGRATED SAMPLE REF: Regulations 9-1-302, 9-1-304 through 310, 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of total ...
Read MoreSep 27, 1996 ... Source Test Procedure ST-19B TOTAL SULFUR OXIDES, INTEGRATED SAMPLE REF: Regulations 9-1-302, 9-1-304 through 310, 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of total ...
Thg10 1, 1996 ... Source Test Procedure ST-24 TANK SAMPLING FOR ORSAT ANALYSIS (CO, CO , O ) 2 2 REF: Regulations 6-310.1, 8-1-110.3, 10-3-301, 9-3-301 through 9-3-304 1. APPLICABILITY 1.1 This procedure is used to ...
Read MoreThg10 1, 1996 ... Source Test Procedure ST-24 TANK SAMPLING FOR ORSAT ANALYSIS (CO, CO , O ) 2 2 REF: Regulations 6-310.1, 8-1-110.3, 10-3-301, 9-3-301 through 9-3-304 1. APPLICABILITY 1.1 This procedure is used to ...
Thg5 21, 2012 ... Facility Name: SFPP. L.P. San Jose Terminal #: A4020 Permit for Facility Page #l through April 30,2012 Report for Period November 1,201l Title V Monitoring Verifìcation Semi-Annual Table VII - ...
Read MoreThg5 21, 2012 ... Facility Name: SFPP. L.P. San Jose Terminal #: A4020 Permit for Facility Page #l through April 30,2012 Report for Period November 1,201l Title V Monitoring Verifìcation Semi-Annual Table VII - ...
Jun 1, 2022 ... Compliance Advisory June 9, 2022 Source Testing and Emissions Monitoring Advisory This Compliance Advisory is provided to inform you about activities of the Air District which may affect your ...
Read MoreJun 1, 2022 ... Compliance Advisory June 9, 2022 Source Testing and Emissions Monitoring Advisory This Compliance Advisory is provided to inform you about activities of the Air District which may affect your ...
Thg1 24, 2022 ... PUBLIC VERSION 1 -WITHOUT TRADE SECRETS 2 3 FILED 4 I JAl'l2 4 2022 5 HEARING BOARD BEFORE IBE HEARING BOARD OF THE BAY AREA AIR OUAU1Y 6 MANAOEMENT DISTRICT BAY AREA AIR QUALITY ...
Read MoreThg1 24, 2022 ... PUBLIC VERSION 1 -WITHOUT TRADE SECRETS 2 3 FILED 4 I JAl'l2 4 2022 5 HEARING BOARD BEFORE IBE HEARING BOARD OF THE BAY AREA AIR OUAU1Y 6 MANAOEMENT DISTRICT BAY AREA AIR QUALITY ...
Cập Nhật Lần Cuối: 08/11/2016